CGJDX - SODIUM PHOSPHATE P32 SOLUTION/THERAPEUTIC

  • MSDS: CGJDX
  • Manufacturer: MALLINCKRODT MEDICAL INC
  • Product Name: SODIUM PHOSPHATE P32 SOLUTION/THERAPEUTIC
  • National Stock Number: 6505-00F055244
Product Identification

Product ID:SODIUM PHOSPHATE P32 SOLUTION/THERAPEUTIC
MSDS Date:01/01/1997
FSC:6505
NIIN:00F055244
MSDS Number: CGJDX

Responsible Party
MALLINCKRODT MEDICAL INC
2703 WAGNER PLACE
MARYLAND HEIGHTS, MO 63043-3421
US

Emergency Phone: 314-770-7800

Info Phone: 314-770-7800/314-895-2000

Cage: FO650

Contractor
MALLINCKRODT MEDICAL INC
MARYLAND HEIGHTS, MO 63043-3421 US

Telephone: 314-770-7800/314-895-2000

Cage: FO650

Ingredients

SODIUM PHOSPHATE P 32

CAS: 7635-46-3

Fraction By Weight: <0.001%


SODIUM ACETATE, ANHYDROUS

CAS: 126-96-5

RTECS: AJ4375000

Fraction By Weight: <1%


SODIUM CHLORIDE *97-4*

CAS: 7647-14-5

RTECS: VZ4725000

Fraction By Weight: 0.9%


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 99%

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: MAY CAUSE ASYMPTOMATIC
PHYSIOLOGICAL UPTAKE BY SPECIFIC TARGET ORGANS/TISSUES. EYES:
IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION.

First Aid

First Aid:SKIN: WASH THE AREA THOROUGHLY W/SOAP & WATER. ALWAYS BLOT
DRY. DON'T ABRADE. EYES: WASH W/WATER FOR 15 MINS. OBTAIN MEDICAL
ATTENTION IN ALL CASES.

Fire Fighting

Extinguishing Media:USE ANY MEANS SUITABLE FOR EXTINGUISHING
SURROUNDING FIRE.
Fire Fighting Procedures:WEAR FULL PROTECTIVE CLOTHING & NIOSH-APPROVED
SCBA W/FULL FACEPIECE.
Unusual Fire/Explosion Hazard:NON-FLAMMABLE.

Accidental Release

Spill Release Procedures:IF PRODUCT IS RECEIVED IN A LEAKING
CONDITION/ANY LOSS/RELEASE OF THE RADIOACTIVE CONTENTS OCCURS,
NOTIFY YOUR RADIATION SAFETY DEPARTMENT & MALLINCKRODT. ALL CLEANUP
OPERATIONS SHOULD BE PERFORMED AC CORDING TO STANDARD OPERATING
PROCEDURES.

Handling

Handling and Storage Precautions:STORE AT 59-86F. HANDLING TIME SHOULD
BE KEPT TO A MINIMUM & SHIELDING SHOULD BE USED. HANDLING DEVICES
SUCH AS SYRINGE SHIELDS & TONGS SHOULD BE USED
Other Precautions:STORAGE & DISPOSAL SHOULD BE CONTROLLED IAW/FEDERAL,
STATE & LOCAL REGULATIONS. AVOID CONTACT W/RADIOACTIVE CONTENTS
WHICH WOULD CAUSE UNNECESSARY EXPOSURE TO RADIATION. THE VIAL
SHOULD BE KEPT W/IN I T'S CONTAINER/W/IN HEAVIER SHIELDING.

Exposure Controls

Respiratory Protection:NOT EXPECTED TO REQUIRE PERSONAL RESPIRATOR
USAGE.
Ventilation:NOT REQUIRED.
Protective Gloves:DISPOSABLE PLASTIC/LATEX/RUBBER
Eye Protection:SAFETY GLASSES
Other Protective Equipment:LABCOAT.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. RADIOACTIVE DRUGS MUST BE HANDLED BY QUALIFIED PERSONNEL.
Supplemental Safety and Health
NO SMOKING, EATING/DRINKING SHOULD BE ALLOWED. PROMPTLY REMOVE ANY
CONTAMINATION FROM THE SKIN, EYES/CLOTHING.

Chemical Properties

Boiling Pt:B.P. Text:212F
Melt/Freeze Pt:M.P/F.P Text:32F
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR COLORLESS LIQUID SEALED IN A 10 ML GLASS
VIAL; ODORLESS

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:HEAT
Hazardous Decomposition Products:MAY EMIT RADIOACTIVE FUMES CONTAINING
P-32.

Disposal

Waste Disposal Methods:IF NOT RADIOACTIVE/BIOHAZARD WASTE, DISPOSE OF
IAW/FEDERAL, STATE & LOCAL REGULATIONS. UN2982.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,